1
|
04-Oct-2023
|
ID Fan # 5 |
SCX450F, 630 KW, KEC
|
NGD450,750KW,CG
|
No |
|
|
|
2
|
16-Nov-2023
|
Cr # 224 AH |
HOR1171-6D,17KW,SSW
|
HOR1171-6D,17KW,SSW
|
Yes |
Stator winding burnt. Motor physically damaged and beyond repair |
|
|
3
|
20-Dec-2023
|
Cr # 224 CT |
AMK160L6, 8.5KW, NGEF |
KS160L6, 8.5KW, Marathon |
Yes |
Motor was taking high current and tripping frequently |
|
|
4
|
02-Jan-2024
|
SLURRY PUMP |
LD180MKII, 22KW |
180L4, 22KW, LHP |
Yes |
Bearing Problem |
|
|
5
|
04-Jan-2024
|
TONG |
KBH125B4 |
KBH125B4 |
Yes |
Single Phasing occurred |
|
|
6
|
30-Jan-2024
|
CR # 212 M.H. |
355M10 |
355M10 |
Yes |
Abnormal Sound & High Current. May be Internal winding failure. |
|
|
7
|
29-Jan-2024
|
Cr # 230 AH |
KS280MCR |
AMK280M8 |
Yes |
Motor winding showing grounded. |
|
|
8
|
18-Mar-2024
|
CR # 212 M.H. |
355M10 |
355M10 |
Yes |
Stator grounded |
|
|
9
|
24-Mar-2024
|
ID Fan # 4 |
DC450F3 , 630 KW, MARATHON |
SCX450F, 630 KW, KEC |
Yes |
Smoke from inside the motor. Motor burnt |
|
|
10
|
17-Apr-2024
|
CR # 200 MH |
355S8, 70KW, CG |
355S8, 70KW, CG |
Yes |
Threaded portion of rotor damaged |
|