| SL # | Date | Drive | Out Motor | In Motor | Failed ? | Failure Description | Actions |
|---|---|---|---|---|---|---|---|
| 6 | 30-Jan-2024 | CR # 212 M.H. | 355M10 | 355M10 | Yes | Abnormal Sound & High Current. May be Internal winding failure. | |
| 7 | 29-Jan-2024 | Cr # 230 AH | KS280MCR | AMK280M8 | Yes | Motor winding showing grounded. | |
| 8 | 18-Mar-2024 | CR # 212 M.H. | 355M10 | 355M10 | Yes | Stator grounded | |
| 9 | 24-Mar-2024 | ID Fan # 4 | DC450F3 , 630 KW, MARATHON | SCX450F, 630 KW, KEC | Yes | Smoke from inside the motor. Motor burnt | |
| 10 | 17-Apr-2024 | CR # 200 MH | 355S8, 70KW, CG | 355S8, 70KW, CG | Yes | Threaded portion of rotor damaged |