Work Order Details
| Work Order # () | 5000028225 |
| Eqpt Class | 03-Feb-2025 |
| Eqpt Class | RSE_MOTOR_SQ_HT |
| Cat # | 90816500 |
| Serial # | 3190805-01 |
| Description | 90816500001 |
| Description | SCX450F, 630 KW, KEC |
| Rating (KW) | 630.00 |
| Frame | SCX450F |
| Make | KEC |
| Job | REWINDING |
| Work Order Status | APPROVED |
| Receipt at RS(E) | |
| Job Completed | |
| Job Delivered | |
| Kept in Location | (Unknown) |
| For Drives | |
| Used in | |
| Used On | |
| Remarks | Removed from ID Fan # 4. RS(E) gave ITC # 24147 Dt.03-Mar-2025. Stator winding burnt, both end cover housing loose, both bearings (6326C3,NU322C) defective. |